Flexibility
- 3 different sizes from 30 up to 300 kW
- Different generator, PV and load sizes
Easy to use
- Integrated AC distribution for Sunny Island, generator, PV
- Integrated load-shedding contactor
Safe
- Active anti-islanding
- Reverse current monitoring
- Automatic bypass for the generator
Durable
- IP65 high protection class
- 5 years SMA warranty
| General | Multicluster-Box 6 | Multicluster-Box 12 | Multicluster-Box 36* |
| Number of phases | 3-phase | 3-phase | 3-phase |
| Nominal AC-voltage | 230 V (L, N), 400 V (L1, L2) |
230 V (L, N), 400 V (L1, L2) |
230 V (L, N), 400 V (L1, L2) |
| AC voltage range | 172.5 V – 265 V, 300 V – 433 V |
172.5 V – 265 V, 300 V – 433 V |
172.5 V – 250 V, 300 V – 433 V |
| Nominal AC frequency (range) | 50 Hz (40 Hz – 70 Hz) | 50 Hz (40 Hz – 70 Hz) | 50 Hz (40 Hz – 70 Hz) |
| Permitted grid structure | TN | TN | TN |
| Dimensions (W / H / D) in mm | 760 / 760 / 210 | 1000 / 1400 / 300 | 1200 / 2000 / 850 |
| Mounting type | suspended | standing on a plinth | standing on a plinth |
| Weight | 60 kg | 140 kg | 400 kg |
| Connections for Sunny Island | |||
| Number of devices | 6 | 12 | 36 |
| Continuous AC power / AC current at 25 °C |
30 kW / 3 x 44 A | 60 kW / 3 x 87 A | 180 kW / 3 x 260 A |
| Continuous AC power / AC current at 45 °C |
24 kW / 3 x 35 A | 48 kW / 3 x 70 A | 144 kW / 3 x 209 A |
| AC power / AC current for 30 min. | 40 kW | 80 kW | 234 kW / 3 x 340 A |
| AC power / AC current for 1 min. | 50 kW | 100 kW | 300 kW / 3 x 440 A |
| Fuses | Circuit breaker C32A | Circuit breaker C32A | Circuit breaker C32A |
| PV system connection | |||
| Number | 1 (3-phase) | 1 (3-phase) | 1 (3-phase) |
| Continuous AC-power PV / continuous AC-current PV at 25 °C | 55 kW / 3 x 80A | 110 kW / 3 x 160 A | 300 kW / 3 x 435 A (AC1) |
| Fuses | — | — | — |
| Connection of consumers | |||
| Number | 1 (3-phase) | 1 (3-phase) | 1 (3-phase) |
| Nominal power / current at 25 °C | 55 kW / 3 x 80A | 110 kW / 3 x 160 A | 300 kW / 3 x 435 A (AC1) |
| Fuses | NH00 | NH00 | NH3 |
| Generator connection | |||
| Number | 1 (3-phase) | 1 (3-phase) | 1 (3-phase) |
| Nominal generator power / current at 25 °C |
55 kW / 3 x 80A | 110 kW / 3 x 160 A | 300 kW / 3 x 435 A (AC1) |
| Fuses | NH00 | NH00 | NH3 |
| Features / function | |||
| Warranty: (5 / 10 / 15 / 20 / 25 years) | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. |
| Certificates and approvals | CE | CE | CE |
| Ambient conditions | |||
| Ambient temperature (SBU, AS-box) | –25 °C ... +50 °C | –25 °C ... +50 °C | –25 °C ... +60 °C |
| Protection class (according IEC 60529) | IP65 | IP65 | IP55 |
| Air humidity | 0 % ... 100 % | 0 % ... 100 % | 0 % ... 100 % |
| Accessories | |||
| Communication cables | yes | yes | yes |
| Multicluster Piggy-Back | opt. | opt. | opt. |
| *The technical data for the MC-Box-36.3 is preliminary | |||
| Dated May 2010 | |||
| Type designation | MC-BOX-6.3 | MC-BOX-12.3 | MC-Box-36.3 |
Downloads
Language:
Data sheet
|
1.516 KB |
Multicluster Boxes for SUNNY ISLAND 5048 - For easy set-up of stand-alone and hybrid systems Type: Data sheet Language: English (Worldwide) Document number: CLUSTBOX-DEN102020 Version number: 2.0 |
Installation Guide
|
2.965 KB |
MULTICLUSTER BOX 6.3 / 12.3 - Installation Guide Type: Installation Guide Language: English (Worldwide) Document number: MC-BOX-6_12-IEN093610 Version number: 1.0 |
Technical Description
|
155 KB |
SUNNY ISLAND / SUNNY BACKUP - Multicluster Update Type: Technical Description Language: International Document number: ClusterUpdate-TXX094010 Version number: 1.0 |
|
268 KB |
SUNNY ISLAND Multicluster System - Notes regarding Multicluster Operation Type: Technical Description Language: English (Worldwide) Document number: MCL-Hinweise-TEN093810 Version number: 1.0 |


SMA Feed