Smart Load for SUNNY ISLAND

Smart Load for SUNNY ISLAND

Intelligent Dump Load for Stand-Alone Grids

The Smart Load forms the perfect complement to unregulated energy generators in stand-alone grids, e.g. small, directly-connected wind turbine systems with passive stall power control. If there is a surplus of electrical energy, the Smart Load feeds it into special loads, for example heating cartridges in a hot water tank. This automatic control is extremely fast, non-reactive and offers optimum protection for system components as well as enhanced reliability.

Flexible

  • Applicable from 45 Hz to 65 Hz
  • Parallel connection
  • Suitable for 1-phase and 3-phase operation


Simple

  • Ideal complement for energy sources without active power control
  • Comfortable installation and commissioning


Reliable

  • Minimized AC interference emission thanks to power factor adjustment
  • Integrated power frequency statistics


Durable

  • High protection class IP65
  • 5-year SMA warranty
  Smart Load
6000
Input  
Rated AC input voltage 230 V (1-phase) / 3 x 400 V / 230 V with durable neutral conductor
AC input voltage range 3 x 180 V – 270 V
Rated frequency 50 Hz
Frequency range 45 Hz – 65 Hz
Frequency range (from set value) - 5 Hz ... + 5 Hz
   
Output  
DC voltage range 3 x 0 V – 230 V
Output power per phase (3-phase / 1-phase) 3 x 2 kW / 1 x 6 kW
Terminals for load resistance 3 single resistances at 2 kW or
1 single resistance at 6 kW
   
Protection  
DC short circuit yes
DC no-load operation yes
AC short circuit yes
Overload yes
   
General data  
Dimensions (W / H / D) 435 / 325 / 215 mm
Weight 14 kg
Operating temperature range -25 °C ... +50 °C
Assembly type suspended
Degree of protection (according to IEC 60529) IP65
   
Features  
Warranty (5 / 10 / 15 / 20 / 25 years) yes / opt. / opt. / opt. / opt.
Certificates and approvals CE
   
Type designation SL-6000

Downloads

Language:
Data sheet


1.497 KB

SMA OFF-GRID CONFIGURATOR - Auslegungs- und Simulationsprogramm für Off-Grid-Systeme
Type: Data sheet
Language: German
Document number: OFFGRIDCON-DDE111910
Version number: 1.0


1.022 KB

Smart Load für SUNNY ISLAND - Intelligente Dumpload für Inselnetze
Type: Data sheet
Language: German
Document number: SL6000-DDE102320
Version number: 2.0


1.208 KB

Smart Load for SUNNY ISLAND - Intelligent dumpload for stand-alone grids
Type: Data sheet
Language: English (Worldwide)
Document number: SL6000-DEN102310
Version number: 1.0


129 KB

SMA OFF-GRID CONFIGURATOR - Design and simulation program for off-grid systems
Type: Data sheet
Language: English (US)
Document number: OFFGRIDCON-DUS113911
Version number: 1.1
Technical Description


1.902 KB

SMART LOAD 6000 - Technische Beschreibung
Type: Technical Description
Language: German
Document number: SL6000-TDE081820
Version number: 2.0


2.008 KB

SMART LOAD 6000 - Technical Description
Type: Technical Description
Language: English (Worldwide)
Document number: SL6000-TEN081820
Version number: 2.0
Certificate


237 KB

Herstellererklärung - Made in Germany / Manufacturer‘s Declaration - Made in Germany
Type: Certificate
Language: International
Document number: HK_MiG_OGS-ZEXX113410
Version number: 1.0


48 KB

CE Konformitätserklärung - Smart Load SL 6000
Type: Certificate
Language: German
Document number: SL-CE-12:BD0607
Warranty


208 KB

SMA Werksgarantie - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: German
Document number: GEBED_SI-ZEDE115019
Version number: 1.9


200 KB

SMA Factory Warranty - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: English (Worldwide)
Document number: GEBED_SI-ZEEN115019
Version number: 1.9


198 KB

Garantía de fábrica de SMA - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: Spanish
Document number: GEBED_SI-ZEES115019
Version number: 1.9


202 KB

Garantie usine SMA - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: French
Document number: GEBED_SI-ZEFR115019
Version number: 1.9


200 KB

Garanzia di fabbrica SMA - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: Italian
Document number: GEBED_SI-ZEIT115019
Version number: 1.9


209 KB

Εργοστασιακή εγγύηση SMA - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: Greek
Document number: GEBED_SI-ZEGR115019
Version number: 1.9


266 KB

SMA 厂家保修 - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: Chinese
Document number: GEBED_SI-ZEZH115019
Version number: 1.9


217 KB

SMA 제품 보증 - SUNNY ISLAND/SUNNY BACKUP
Type: Warranty
Language: Korean
Document number: GEBED_SI-ZEKR115019
Version number: 1.9
Catalog


13.799 KB

SUNNY FAMILY 2011/2012 - Off-Grid Solutions - The Future of Solar Technology
Type: Catalog
Language: German
Document number: SFK_OFFGRID-KDE112111
Version number: 1.1


9.300 KB

SUNNY FAMILY 2011/2012 - Off-Grid Solutions - The Future of Solar Technology
Type: Catalog
Language: English (Worldwide)
Document number: SFK_OFFGRID-KEN112111
Version number: 1.1


10.812 KB

SUNNY FAMILY 2011/2012 - Off-Grid Solutions - The Future of Solar Technology
Type: Catalog
Language: Spanish
Document number: SFK_OFFGRID-KES115011
Version number: 1.1


9.905 KB

SUNNY FAMILY 2011/2012 - Off-Grid Solutions - The Future of Solar Technology
Type: Catalog
Language: French
Document number: SFK_OFFGRID-KFR114511
Version number: 1.1


9.844 KB

SUNNY FAMILY 2011/2012 - Off-Grid Solutions - The Future of Solar Technology
Type: Catalog
Language: Greek
Document number: SFK_OFFGRID-KEL113612
Version number: 1.2


8.987 KB

SUNNY FAMILY 2011/2012 - Off-Grid Solutions - The Future of Solar Technology
Type: Catalog
Language: Dutch
Document number: SFK_OFFGRID-KNL114811
Version number: 1.1


8.941 KB

SUNNY FAMILY 2011/2012 - Off-Grid Solutions - The Future of Solar Technology
Type: Catalog
Language: Czech
Document number: SFK_OFFGRID-KCZ120311
Version number: 1.1