Flexible
- For systems from 1 up to 9 kW
- 1- and 3-phase operation, connectable in parallel and modularly extendable
- AC and DC coupling
Usability
- Simple installation
- Complete stand-alone management
- Easy and remote configuration and monitoring with Sunny Remote Control
Efficient
- High efficiency
- Long battery service life
- Reliable state-of-charge evaluation
Durable
- For indoor and outdoor installation
- Excellent overload characteristics
- Very wide temperature range
- 5 years SMA Warranty
| Output data | 2012 | 2224 |
| Nominal AC voltage | 230 V | 230 V |
| Nominal frequency | 50 Hz / 60 Hz | 50 Hz / 60 Hz |
| AC continuous power at 25 °C | 2000 W | 2200 W |
| AC power for 30 min at 25 °C | 2500 W | 2900 W |
| Input data | ||
| Input voltage | 230 V | 230 V |
| Input frequency | 40 - 70 Hz | 40 - 70 Hz |
| Max. input power | 5.75 kW | 5.75 kW |
| Battery data | ||
| Battery voltage (range) | 12 V (8.4 V - 15.6 V) | 24 V (16.8 V - 31.5 V) |
| Continuous charging current | 160A | 80A |
| Efficiency | ||
| Max. efficiency (typ.) | 93.0 % | 93.6 % |
| Protection class | ||
| per DIN EN 60529 | IP 54 | IP 54 |
| Device protection | short-circuit, overload, overheating | short-circuit, overload, overheating |
| Mechanical data | ||
| width × height × depth (in mm) | 470 x 445 x 185 | 470 x 445 x 185 |
| weight | 19 kg | 19 kg |
Downloads
Language:
Firmware
|
308 KB |
SUNNY ISLAND 2012 / 2224 - Firmware-Update V3.012/3.010 Type: Firmware Language: International Document number: SUNNY-ISLAND-2012-2224_3012-3010 |
Catalog
|
1.970 KB |
WINDY BOY - Inverter for Wind Energy Power Plants Type: Catalog Language: English (Worldwide) Document number: WINDYBOY-KEN101613 Version number: 1.3 |
Data sheet
|
511 KB |
SUNNY REMOTE CONTROL - More fl exibility for Sunny Island and Sunny Backup Type: Data sheet Language: English (Worldwide) Document number: SRC1-DEN083911 Version number: 1.1 |
|
1.440 KB |
SUNNY ISLAND 2012 / 2224 - Compact and powerful for small stand-alone systems Type: Data sheet Language: English (Worldwide) Document number: SI2012_2224-DEN102020 Version number: 2.0 |
Technical Manual
|
420 KB |
Questionnaire on Off-grid System Dimensioning Type: Technical Manual Language: English (Worldwide) Document number: QUESTIONNAIRE-UEN090512d Version number: 1.2 |
|
87 KB |
Questionnaire on Off-grid System Dimensioning Type: Technical Manual Language: English (Worldwide) Document number: QUESTIONNAIRE-UEN090512 Version number: 1.2 |
Technical information
|
387 KB |
PV inverter - Usage and settings of PV inverters in island grids and backup systems Type: Technical information Language: English (Worldwide) Document number: SB-OffGrid-UEN091911 Version number: 1.1 |
Technical Description
|
6.128 KB |
SUNNY ISLAND 2012 / 2224 - Technical Description Type: Technical Description Language: English (Worldwide) Document number: SI2012_2224-TEN091830 Version number: 3.0 |
Certificate
|
580 KB |
EC Declaration of Conformity - SUNNY ISLAND 2012, 2224, 3324, 4248, 5048 Type: Certificate Language: English (Worldwide) Document number: CE_SI-ZEN094811 Version number: 1.1 |
Warranty
|
153 KB |
SMA Factory Warranty - Sunny Island/Sunny Backup Type: Warranty Language: English (Worldwide) Document number: GEBED_SI-ZEN095215 Version number: 1.5 |
|
157 KB |
Order of an Extension of the SMA Factory Warranty Type: Warranty Language: English (Worldwide) Document number: B-GV_ZEN095114 Version number: 1.4 |



SMA Feed