| Sunny Island 3324 |
Sunny Island 4248 |
|
| AC output (loads) | ||
| Nominal AC voltage / adjustable | 230 V / 202 V – 253 V | 230 V / 202 V – 253 V |
| Nominal AC frequency / adjustable | 50 Hz / 45 Hz ... 55 Hz | 50 Hz / 45 Hz ... 55 Hz |
| Continuous AC power (at 25 °C / at 45 °C) | 3300 W / 2300 W | 4200 W / 3400 W |
| AC power at 25 °C for 30 min / 1 min / 3 s | 4200 W / 5000 W / 7300 W | 5400 W / 7000 W / 11400 W |
| Nominal AC current / max. AC current (peak) | 14.5 A / 70 A for approx. 60 ms | 18 A / 100 A for approx. 60 ms |
| THD output voltage / power factor at rated power | 3 % / -1 ... +1 | 3 % / -1 ... +1 |
| AC input (generator or grid) | ||
| AC input voltage / range | 230 V / 172,5 V – 250 V | 230 V / 172,5 V – 250 V |
| AC input frequency / range | 50 Hz / 40 Hz ... 60 Hz | 50 Hz / 40 Hz ... 60 Hz |
| Max. input current / adjustable | 56 A / 2 A ... 56 A | 56 A / 2 A ... 56 A |
| Max. input power | 12.8 kW | 12.8 kW |
| Battery DC input | ||
| Battery voltage / range | 24 V / 21 V – 32 V | 48 V / 41 V – 63 V |
| Max. battery charging current / continuous charging current at 25 °C | 140 A / 104 A | 100 A / 80 A |
| Battery type / battery capacity | Lead / 100 Ah ... 6000 Ah | Lead / 100 Ah ... 6000 Ah |
| Charge control | IUoU process | IUoU process |
| Efficiency / self-consumption | ||
| Max. efficiency | 94.5 % | 95 % |
| Self-consumption with no load / standby | 22 W / 4 W | 22 W / 4 W |
| Protection | ||
| DC reverse polarity protection / DC fuse | yes / yes | yes / yes |
| AC short circuit / AC overload | yes / yes | yes / yes |
| Overtemperature / battery deep discharge | yes / yes | yes / yes |
| General data | ||
| Dimensions (W / H / D) | 390 / 590 / 245 mm | 390 / 590 / 245 mm |
| Weight | 39 kg | 39 kg |
| Operating temperature range | -25 °C ... +50 °C | -25 °C ... +50 °C |
| Degree of protection (according to IEC 60529) | Interior assembly (IP30) | Interior assembly (IP30) |
| Features / function | ||
| Operation & display / multifunctional relay | Intern / 2 | Intern / 2 |
| 3-phase systems / parallel connection | — / — | — / — |
| Integrated bypass / multicluster operation | — / — | — / — |
| State of charge calculation / full charge / equalization charge | — / yes / yes | — / yes / yes |
| Integrated soft start / generator support | yes / — | yes / — |
| Battery temperature sensor / communication lines | yes / — | yes / — |
| Warranty (5 / 10 / 15 / 20 / 25 years) | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. |
| Certificates and approvals | www.SMA-Solar.com | www.SMA-Solar.com |
| Accessories | ||
| Battery cable / battery fuse | opt. / opt. | opt. / opt. |
| Interface (RS485 / multicluster PB) | opt. / — | opt. / — |
| Extended generator start "GenMan" | opt. | opt. |
| Load-shedding contactors / external battery current measurement | opt. / — | opt. / — |
| Type designation | SI 3324 | SI 4248 |
Downloads
Language:
Certificate
|
237 KB |
Herstellererklärung - Made in Germany / Manufacturer‘s Declaration - Made in Germany Type: Certificate Language: International Document number: HK_MiG_OGS-ZEXX113410 Version number: 1.0 |
|
142 KB |
Exchange Inverter Declaration Form Type: Certificate Language: English (AU) Document number: GeräteanforderungEN11_AUT |