| Sunny Boy 3300 |
Sunny Boy 3800 |
|
| Input (DC) | ||
| Max. DC power (@ cos φ=1) | 3820 W | 4040 W |
| Max. input voltage | 500 V | 500 V |
| MPP voltage range / rated input voltage | 200 V – 400 V / 200 V | 200 V – 400 V / 200 V |
| Min. input voltage / initial input voltage | 200 V / 250 V | 200 V / 250 V |
| Max. input current | 20 A | 20 A |
| Max. input current per string | 16 A | 16 A |
| Number of independent MPP inputs / strings per MPP input | 1 / 3 | 1 / 3 |
| Output (AC) | ||
| Rated output power (@ 230 V, 50 Hz) | 3300 W | 3800 W |
| Max. apparent AC power | 3600 VA | 3800 VA |
| Nominal AC voltage / range | 220 V, 230 V, 240 V / 180 V – 265 V | 220 V, 230 V, 240 V / 180 V – 265 V |
| AC power frequency / range | 50 Hz, 60 Hz / -4.5 Hz ... +4.5 Hz | 50 Hz, 60 Hz / -4.5 Hz ... +4.5 Hz |
| Rated power frequency / rated power voltage | 50 Hz / 230 V | 50 Hz / 230 V |
| Max. output current | 18 A | 18 A |
| Power factor at rated power | 1 | 1 |
| Adjustable displacement factor | — | — |
| Feed-in phases / connection phases | 1 / 1 | 1 / 1 |
| Efficiency | ||
| Max. efficiency / European efficiency | 95.2 % / 94.4 % | 95.6 % / 94.7 % |
| Protection | ||
| Input-side disconnection device | yes | yes |
| Ground-fault monitoring / grid monitoring | yes / yes | yes / yes |
| DC surge arrester Type II, can be integrated | — | — |
| DC reverse-polarity protection / AC short-circuit current capability / galvanically isolated | yes / yes / yes | yes / yes / yes |
| All-pole sensitive residual current monitoring unit | — | — |
| Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) | I / III | I / III |
| General Data | ||
| Dimensions (W / H / D) | 450 / 352 / 236 mm (17.7 / 13.9 / 9.3 inch) |
450 / 352 / 236 mm (17.7 / 13.9 / 9.3 inch) |
| Weight | 38 kg / 83.6 lb | 38 kg / 83.6 lb |
| Operating temperature range | -25 °C ... +60 °C / -13 °F ... +140 °F | -25 °C ... +60 °C / -13 °F ... +140 °F |
| Noise emission (typical) | 40 dB(A) | 42 dB(A) |
| Internal consumption (night) | 0.1 W | 0.1 W |
| Topology | LF transformer | LF transformer |
| Cooling concept | OptiCool | OptiCool |
| Degree of protection (according to IEC 60529) | IP65 | IP65 |
| Degree of protection of connection area (according to IEC 60529) | IP65 | IP65 |
| Climatic category (according to IEC 60721-3-4) | 4K4H | 4K4H |
| Maximum permissible value for relative humidity (non-condensing) | 100 % | 100 % |
| Features | ||
| DC terminal | SUNCLIX | SUNCLIX |
| AC terminal | Connector | Connector |
| Display | Text line | Text line |
| Interface: RS485 / Bluetooth | opt. / opt. | opt. / opt. |
| Warranty: 5 / 10 / 15 / 20 / 25 years | yes / opt. / opt. / opt. / opt. | yes / opt. / opt. / opt. / opt. |
| Multi-function relay | — | — |
| Certificates and approvals (more available on request) | CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, CER/06/190, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, PPDS, UTE C15-712-1, C10/11 | CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, CER/06/190, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, PPDS, UTE C15-712-1, C10/11 |
| * Does not apply to all national deviations of EN 50438 ** Only applies to IT option |
||
| Data at nominal conditions | ||
| Type designation | SB 3300 | SB 3800 |
Downloads
Language:
Data sheet
|
325 KB |
SUNNY BOY 3300 / 3800 - The generalist Type: Data sheet Language: English (AU) Document number: SB33_38_38V-DAU104442 Version number: 4.2 |
Installation Guide
|
543 KB |
SUNNY BOY / SUNNY MINI CENTRAL / WINDY BOY - Kurzanleitung für Firmware-Update / Quick Reference Guide for Firmware Update Type: Installation Guide Language: International Document number: CG_UpdFW-IXX104520 Version number: 2.0 |
|
3.057 KB |
ESHV-P-NR / ESHV-N-NR - Installation Guide (DE, EN, FR, ES, IT, GR, CZ, PT, NL) Type: Installation Guide Language: International Document number: ESHV-IXX103013 Version number: 1.3 |
Certificate
|
183 KB |
Gleichheitsbescheinigung - SUNNY BOY/WINDY BOY Type: Certificate Language: International Document number: GHB_SBWB-ZEXX112612 Version number: 1.2 |
|
215 KB |
Herstellererklärung - Made in Germany / Manufacturer‘s Declaration - Made in Germany Type: Certificate Language: International Document number: HK_MiG-ZXX112110 Version number: 1.0 |
|
913 KB |
Declaration of Conformity according to AS4777 and EN 60335-1 - SUNNY BOY 3300 / 3800, WINDY BOY 3300 / 3800 Type: Certificate Language: English (AU) Document number: AS4777_EN60335-1_SB33-38_WB33-38-ZEN093510 Version number: 1.0 |
|
317 KB |
Certificate of Suitability 9123 - SUNNY BOY 3300/3800 and WINDY BOY 3300/3800 Type: Certificate Language: English (AU) Document number: CoS_SB33-38-WB33-38_ZAU092010 Version number: 1.0 |
|
142 KB |
Exchange Inverter Declaration Form Type: Certificate Language: English (AU) Document number: GeräteanforderungEN11_AUT |
|
93 KB |
Declaration of Conformity to AS4777 - Sunny Boy 700, SB 1100, SB 1700, SB 2500, SB 3300, SB 3800, Sunny Mini Central 5000A, SMC 6000A Type: Certificate Language: English (AU) Document number: SB-AS4777-11:BE2707 |