SUNNY MINI CENTRAL 5000A / 6000A

SUNNY MINI CENTRAL 5000A / 6000A

Proven technology for a multitude of applications

The Sunny Mini Central 5000A and 6000A are installed wherever galvanic isolation is required. This means they can be universally used for many different types of connections. In this way, the Sunny Mini Centrals can be used with crystalline cells as well as thin-film modules. Thanks to their graduated performance classes, they offer the highest degree of flexibility in plant design. The Sunny Mini Centrals 5000A and 6000A are also ideal for three-phase systems.

Powerful

  • OptiCool active temperature management
  • OptiTrac MPP tracking for best tracking efficiency


Reliable

  • Galvanic isolation
  • Integrated ESS DC switch-disconnector
  • SMA Power Balancer for three-phase grid connection


Flexible

  • Suitable for PV array grounding


Simple

  • SUNCLIX DC plug system
  Sunny Mini Central
5000A
Sunny Mini Central
6000A
Input (DC)    
Max. DC power (@ cos φ=1) 5750 W 6300 W
Max. input voltage 600 V 600 V
MPP voltage range / rated input voltage 246 V – 480 V / 246 V 246 V – 480 V / 246 V
Min. input voltage / initial input voltage 211 V / 300 V 211 V / 300 V
Max. input current 26 A 26 A
Max. input current per string 26 A 26 A
Number of independent MPP inputs / strings per MPP input 1 / 4 1 / 4
     
Output (AC)    
Rated output power (@230 V, 50 Hz) 5000 W 6000 W
Max. apparent AC power 5500 VA 6000 VA
AC nominal voltage / range 220 V, 230 V, 240 V / 160 V – 265 V 220 V, 230 V, 240 V / 160 V – 265 V
AC power frequency / range 50 Hz, 60 Hz / -6 Hz ... +5 Hz 50 Hz, 60 Hz / -6 Hz ... +5 Hz
Rated power frequency / rated power voltage 50 Hz / 230 V 50 Hz / 230 V
Max. output current 26 A 26 A
Power factor at rated output power 1 1
Adjustable displacement factor
Feed-in phases / connection phases 1 / 1 1 / 1
Power balancing yes yes
     
Efficiency    
Max. efficiency / European efficiency 96.1 % / 95.3 % 96.1 % / 95.3 %
     
Protection    
Reverse current protection / input-side disconnection device — / yes — / yes
Ground fault monitoring / grid monitoring yes / yes yes / yes
DC reverse-polarity protection / AC short-circuit current capability / galvanically isolated yes / yes / yes yes / yes / yes
All-pole sensitive residual current monitoring unit
Protection class (according to IEC 62103) / overvoltage category (according to IEC 60664-1) I / III I / III
     
General Data    
Dimensions (W / H / D) 468 / 613 / 242 mm
(18.4 / 24.1 / 9.5 inch)
468 / 613 / 242 mm
(18.4 / 24.1 / 9.5 inch)
Weight 62 kg / 136.69 lb 63 kg / 138.89 lb
Operating temperature range -25 °C ... +60 °C /
-13 °F ... 140 °F
-25 °C ... +60 °C /
-13 °F ... 140 °F
Noise emission (typical) 42 dB(A) 42 dB(A)
Internal consumption (night) 0.25 W 0.25 W
Topology LF transformer LF transformer
Cooling concept OptiCool OptiCool
Degree of protection (according to IEC 60529) IP65 IP65
Degree of protection of connection area (according to IEC 60529) IP65 IP65
Climatic category (according to IEC 60721-3-4) 4K4H 4K4H
Maximum permissible value for relative humidity (non-condensing) 100 % 100 %
     
Features    
DC terminal SUNCLIX SUNCLIX
AC terminal Screw terminal Screw terminal
Display Text line Text line
Interface: RS485 / Bluetooth opt. / opt. opt. / opt.
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt.
Certificates and approvals (more available on request) CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, PPDS, UTE C15-712-1, C10/11, IEC 61727 CE, VDE0126-1-1, DK 5940 ED2.2**, G83/1-1, RD 1663/2000, RD 661/2007, PPC, AS4777, EN 50438*, UTE C15-712-1, C10/11, PPDS, IEC 61727
     
* Does not apply to all national deviations of EN 50438
** Only applies to IT option
   
Data at nominal conditions    
Type designation SMC 5000A SMC 6000A

Downloads

Language:
Data sheet


470 KB

SUNNY MINI CENTRAL 4600A / 5000A / 6000A - Proven technology for flexible applications
Type: Data sheet
Language: English (AU)
Document number: SMC4600_6000A-DAU103321
Version number: 2.1
Installation Guide


543 KB

SUNNY BOY / SUNNY MINI CENTRAL / WINDY BOY - Kurzanleitung für Firmware-Update / Quick Reference Guide for Firmware Update
Type: Installation Guide
Language: International
Document number: CG_UpdFW-IXX104520
Version number: 2.0


7.006 KB

PBL-SMC-10-NR - Installation Guide
Type: Installation Guide
Language: International
Document number: PBL-SMC-10-NR-IXX082210
Version number: 1.0


3.057 KB

ESHV-P-NR / ESHV-N-NR - Installation Guide (DE, EN, FR, ES, IT, GR, CZ, PT, NL)
Type: Installation Guide
Language: International
Document number: ESHV-IXX103013
Version number: 1.3
Certificate


183 KB

Gleichheitsbescheinigung - SUNNY BOY/WINDY BOY
Type: Certificate
Language: International
Document number: GHB_SBWB-ZEXX112612
Version number: 1.2


215 KB

Herstellererklärung - Made in Germany / Manufacturer‘s Declaration - Made in Germany
Type: Certificate
Language: International
Document number: HK_MiG-ZXX112110
Version number: 1.0


914 KB

Declaration of Conformity according to AS4777 and EN 60335-1 - SUNNY MINI CENTRAL 5000A / 6000A, WINDY BOY 5000A / 6000A
Type: Certificate
Language: English (AU)
Document number: AS4777_EN60335-1_SMC50-60A_WB50-60A-ZEN093510
Version number: 1.0


128 KB

Certificate of Suitability 9125 and Variation/s - SUNNY MINI CENTRAL 5000A / 6000A and WINDY BOY 5000A / 6000A
Type: Certificate
Language: English (AU)
Document number: CoS_AS4417_ZAU093010
Version number: 1.0


1.565 KB

VARIATION TO CERTIFICATE OF SUITABILITY: 9125 - SUNNY MINI CENTRAL 5000A/6000A and WINDY BOY 5000A/6000A
Type: Certificate
Language: English (AU)
Document number: CoS_SMC6000A-ZAU110710
Version number: 1.0


142 KB

Exchange Inverter Declaration Form
Type: Certificate
Language: English (AU)
Document number: GeräteanforderungEN11_AUT


93 KB

Declaration of Conformity to AS4777 - Sunny Boy 700, SB 1100, SB 1700, SB 2500, SB 3300, SB 3800, Sunny Mini Central 5000A, SMC 6000A
Type: Certificate
Language: English (AU)
Document number: SB-AS4777-11:BE2707