SUNNY MINI CENTRAL 7000HV

The champion for thin-film projects

Greater input voltage range – lower installation costs: with the Sunny Mini Central 7000HV, more modules can be connected in series than is possible with common inverters. This reduces cabling costs on the DC side and simplifies the installation. Because of its galvanic separation, the Sunny Mini Central 7000HV can be used with both crystalline cells and thin-film modules. Its performance range permits the installation of large PV systems made up of smaller units, which allows for detailed system monitoring.

Efficient

  • OptiCool active temperature management
  • The best tracking efficiency with OptiTrac MPP tracking


Safe

  • Galvanic isolation
  • Integrated ESS DC loaddisconnecting unit
  • SMA Power Balancer for threephase grid connection


Flexible

  • Input voltage range of up to 800 V
  • Suitable for generator grounding
Input (DC) Sunny Mini Central 7000 HV
Max. DC power 7500 W
Max. DC voltage 800 V
PV-voltage range, MPPT 335 V – 560 V
Max. input current 23 A
Number of MPP trackers 1
Max. number of strings (parallel) 4
Output (AC)  
Nominal AC ouput 6650 W
Max. AC power 7000 W
Max. output current 31 A
Nominal AC voltage / range 220 V – 240 V / 180 V – 260 V
AC grid frequency (self-adjusting) / range 50 Hz / 60 Hz / ± 4.5 Hz
Phase shift (cos φ) 1
AC connection / power balancing single-phase / yes
Efficiency  
Max. efficiency 96.1 %
Euro-Eta 95.3 %
Protection devices  
DC reverse polarity protection yes
ESS DC load-disconnecting switch yes
AC short-circuit protection yes
Ground fault monitoring yes
Grid monitoring (SMA Grid Guard) yes
Galvanically isolated yes
General Data  
Dimensions (W / H / D) in mm 468 / 613 / 242
Weight 65 kg
Operating temperature range –25 °C ... +60 °C
Noise emission (typical) ≤ 41 dB(A)
Consumption: operating (standby) / night <7 W / 0.25 W
Topology LF transformer
Cooling concept OptiCool
Mounting location: indoors / outdoors (IP65) yes / yes
Features  
DC connection: MC3 / MC4 / Tyco opt. / yes / opt.
AC connection: screw terminal yes
LCD yes
Interfaces: Bluetooth / RS485 opt. / opt.
Warranty: 5 years / 10 years yes / opt.
Certificates and approvals www.SMA.de
   
Data at nominal conditions –
Last update: March 2009
 
Type Designation SMC 7000HV

Downloads

Language:
Data sheet


300 KB

SUNNY BOY / SUNNY MINI CENTRAL - Our service – Your benefits
Type: Data sheet
Language: English (Worldwide)
Document number: SBSERVICE-DEN084710
Version number: 1.0


364 KB

SUNNY MINI CENTRAL 7000HV - The champion for thin-film projects
Type: Data sheet
Language: English (Worldwide)
Document number: SMC7000HV-DEN100326
Version number: 2.6


662 KB

Application for the Personal Right
Type: Data sheet
Language: English (Worldwide)
Document number: Grid-guard-ZEN090711
Version number: 1.1
User Manual


1.436 KB

SUNNY MINI CENTRAL 7000HV - User Manual
Type: User Manual
Language: English (Worldwide)
Document number: SMC70HV-BEN101210
Version number: 1.0


1.619 KB

SUNNY BOY / SUNNY MINI CENTRAL - User Manual
Type: User Manual
Language: English (Worldwide)
Document number: SB_SMC-BEN092840
Version number: 4.0
Installation Guide


7.006 KB

PBL-SMC-10-NR - Installation Guide
Type: Installation Guide
Language: International
Document number: PBL-SMC-10-NR-IXX082210
Version number: 1.0


2.524 KB

SUNNY MINI CENTRAL 7000HV / 7000HV-11 - Installation Guide
Type: Installation Guide
Language: English (Worldwide)
Document number: SMC70HV-IEN101250
Version number: 5.0
Technical information


380 KB

Grid forms - Overview of the compatibility between common grid forms and SMA inverters - SUNNY BOY / SUNNY MINI CENTRAL / SUNNY TRIPOWER
Type: Technical information
Language: English (Worldwide)
Document number: Netzformen-UEN094710
Version number: 1.0


420 KB

Capacitive Discharge Currents - Information on the system layout for transformerless inverters SUNNY BOY / SUNNY MINI CENTRAL
Type: Technical information
Language: English (Worldwide)
Document number: Ableitstrom-UEN092510
Version number: 1.0


325 KB

Criteria for selecting an RCD Use of residual current devices (RCD) with SUNNY BOY and SUNNY MINI CENTRAL
Type: Technical information
Language: English (Worldwide)
Document number: RCD-UEN102412
Version number: 1.2


707 KB

Three phase connection - with SUNNY MINI CENTRAL
Type: Technical information
Language: English (Worldwide)
Document number: NetzSMC-UEN084110
Version number: 1.0


376 KB

COM-B - Communication distribution box for large-scale PV plants wit Sunny Central, Sunny Mini Central or Sunny Tripower
Type: Technical information
Language: English (Worldwide)
Document number: COM-B-UEN100422
Version number: 2.2


279 KB

Reverse Current - Advice on generator configuration for PV systems using Sunny Mini Central
Type: Technical information
Language: English (Worldwide)
Document number: Rueckstrom-UEN083010
Version number: 1.0


356 KB

Line Circuit Breaker - Sizing of Suitable Line Circuit Breakers for inverters under PV-specific conditions
Type: Technical information
Language: English (Worldwide)
Document number: LSS-UEN083620
Version number: 2.0


253 KB

COM-C - Communication distribution box for large-scale PV plants with Sunny Central or Sunny Mini Central
Type: Technical information
Language: English (Worldwide)
Document number: COM-C-UEN093320
Version number: 2.0


389 KB

Grid Connection - Influence of the grid conditions in terms of connected power of PV inverters
Type: Technical information
Language: English (Worldwide)
Document number: Netzanschluss-UEN083010
Version number: 1.0


97 KB

Mounting on wooden grounding - Installation restrictions for mounting Sunny Boys and Sunny Mini Centrals to wood
Type: Technical information
Language: English (Worldwide)
Document number: HolzUnt-UEN082610
Version number: 1.0


261 KB

Measurement accuracy - Energy values and efficiency for PV Inverter Sunny Boy and Sunny Mini Central
Type: Technical information
Language: English (Worldwide)
Document number: Messgenau-UEN092520
Version number: 2.0


537 KB

Module Technology - SMA inverters provide the optimal solution for any module
Type: Technical information
Language: English (Worldwide)
Document number: Duennschicht-UEN093821
Version number: 2.1
Technical Description


992 KB

COMMUNICATION BOX (COM-B) - Technical Description
Type: Technical Description
Language: English (Worldwide)
Document number: COM-B-TEN095021
Version number: 2.1


1.232 KB

SUNNY BOY / SUNNY MINI CENTRAL - Operating Parameters
Type: Technical Description
Language: English (Worldwide)
Document number: SB_SMC_Par-TEN092830
Version number: 3.0
Certificate


68 KB

Declaration by the Manufacturer for usage of Residual Current Devices type A with SUNNY BOY and SUNNY MINI CENTRAL
Type: Certificate
Language: English (Worldwide)
Document number: EK_RCD-SBSMC-ZEN102613
Version number: 1.3
Warranty


154 KB

SMA Factory Warranty - Sunny Boy, Windy Boy, Sunny Mini Central, Sunny Tripower, Sunny Boy Control (Light, Plus), Sunny Beam, Sunny WebBox, Sunny Matrix, Sunny Sensor Box, Power Reducer Box, PV Offset Box
Type: Warranty
Language: English (Worldwide)
Document number: GEBED_SBSMC-ZEN094616
Version number: 1.6


157 KB

Order of an Extension of the SMA Factory Warranty
Type: Warranty
Language: English (Worldwide)
Document number: B-GV_ZEN095114
Version number: 1.4
Promotion Material


1.397 KB

SUNNY MINI CENTRAL / SUNNY TRIPOWER - String inverter
Type: Promotion Material
Language: English (Worldwide)
Document number: SMCPOSTER-AEN100410
Version number: 1.0
Practical Example