| Input (DC) | 1100 | 1700 |
| Max. DC input voltage | 400 V | 400 V |
| Operating range "Turbine Mode" | 139 ... 400 V | 139 ... 400 V |
| Min. idle input voltage for activation "Turbine Mode" | 150 V | 150 V |
| DC nominal operating voltage | 180 V | 180 V |
| Recommended generator power at 2500 full-load hours per year | 900 W | 1395 W |
| Recommended generator power at 5000 full-load hours per year | 800 W | 1240 W |
| Max. input current (Imax) | 10.0 A | 12.6 A |
| Internal consumption | < 4 W | < 5 W |
| DC voltage ripple (Upp) | < 10% | < 10% |
| DC isolator | DC connector | DC connector |
| Ground fault monitoring | standard | standard |
| Reverse polarity prevention | standard | standard |
| Grid connection | AC connector | AC connector |
| Output data (AC) | ||
| Max. AC power | 1100 W | 1700 W |
| Nominal AC power | 1000 W | 1550 W |
| Internal consumption while idle | 0.1 W | 0.1 W |
| Autom. 50/60 Hz recognition | standard | standard |
| Efficiency | ||
| Max. efficiency | 93.0 % | 93.5 % |
| Euro-eta | 91.6 % | 91.8 % |
Downloads
Language:
PC Software
|
7.298 KB |
WINDY BOY Setup Tool Type: PC Software Language: International Document number: Windy_Boy_Setup_Tool Version number: 1.0 |
Catalog
|
4.217 KB |
Windy Boy - Grid Connection of Small Wind Turbine Systems Type: Catalog Language: English (Worldwide) Document number: WINDYBOY-KEN075112 Version number: 1.2 |
Data sheet
|
185 KB |
Windy Boy Protection Box - Optimal Protection for Small Wind Power Plants Type: Data sheet Language: English (Worldwide) Document number: WBP-BOX-DEN081211 Version number: 1.1 |
|
314 KB |
WINDY BOY 1100 / 1700 - The Compact Class Type: Data sheet Language: English (Worldwide) Document number: WB1100_1700-DEN091211 Version number: 1.1 |
|
309 KB |
WINDY BOY 1200 / 1700 - The Compact Class Type: Data sheet Language: English (Worldwide) Document number: WB1200_1700-DEN093710 Version number: 1.0 |
User Manual
|
1.092 KB |
WINDY BOY Setup Tool - User Manual Type: User Manual Language: English (Worldwide) Document number: WBSetup-BEN100411 Version number: 1.1 |
|
1.478 KB |
WINDY BOY 1100 / 1200 / 1700 - User Manual Type: User Manual Language: English (Worldwide) Document number: WB11_17-BEN092020-P Version number: 2.0 |
Installation Guide
|
2.028 KB |
WINDY BOY 1100 / 1200 / 1700 - Installation Guide Type: Installation Guide Language: English (Worldwide) Document number: WB11_12_17-IEN094730 Version number: 3.0 |
Technical Manual
|
45 KB |
Answer by fax Type: Technical Manual Language: English (Worldwide) Document number: BZSPLUS-ZEN082311 Version number: 1.1 |
Technical Description
|
1.244 KB |
WINDY BOY - Operating parameters Type: Technical Description Language: English (Worldwide) Document number: WB_Par-TEN093910 Version number: 1.0 |
Certificate
|
285 KB |
EC Declaration of Conformity - WINDY BOY (WB 1100LV, WB 1100, WB 1200, WB 1700, WB 2500, WB 3000, WB 3300, WB 3800, WB 5000A, WB 6000A) Type: Certificate Language: English (Worldwide) Document number: CE_WB-ZEN094713 Version number: 1.3 |
|
197 KB |
Gleichheitsbescheinigung - SUNNY BOY / WINDY BOY Type: Certificate Language: International Document number: GHB_SBWB-ZXX094010 Version number: 1.0 |
Warranty
|
154 KB |
SMA Factory Warranty - Sunny Boy, Windy Boy, Sunny Mini Central, Sunny Tripower, Sunny Boy Control (Light, Plus), Sunny Beam, Sunny WebBox, Sunny Matrix, Sunny Sensor Box, Power Reducer Box, PV Offset Box Type: Warranty Language: English (Worldwide) Document number: GEBED_SBSMC-ZEN094616 Version number: 1.6 |
|
157 KB |
Order of an Extension of the SMA Factory Warranty Type: Warranty Language: English (Worldwide) Document number: B-GV_ZEN095114 Version number: 1.4 |

SMA Feed