SUNNY CENTRAL 500CP XT

SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT

The extended CP XT: more features included

More power: With its extended functions, the new Sunny Central CP XT series is now even more efficient. The reduced specific price, mean that maximum yields are achieved with lower system costs. The Sunny Central CP XT is also optimized for cold temperatures down to -40 °C and with full nominal power in continuous operation up to 50 °C. The inverter includes all grid management functions and is prepared for Q-on-demand. The customized computer platform allows for optimal monitoring and control.

Profitable

  • Up to 1 megawatt system power as standard
  • Significantly reduced specific price thanks to increased power
  • Maximum yields with low system costs

Durable

  • Full nominal power in continuous operation at ambient temperatures up to 50 °C
  • Optimized for extreme climatic conditions between -40 °C and 62 °C
  • Intelligent power management with OptiCool ™

Flexible

  • Wide DC input voltage range for flexible use of various module configurations
  • Perfectly adjusted for the temperature-dependent behavior of PV arrays

Versatile

  • All grid management functions are included, prepared for “Q-ondemand” including pure reactive power operation
  • Customized computer platform for optimal monitoring and control of inverters

Sunny String-Monitor SSM / SSM16-11 / SSM24-11

Detailed plant control: the Sunny String-Monitor watches over the PV array by measuring and comparing individual string currents. This allows certain detection of reductions in performance, which can be directly analyzed via Sunny Central Control. Delivered in an enclosure for wall installation (IP 65).

SMA String Combiner

Sunny Main Box Cabinet

 

Disconnect Unit

Language

Technical information

SUNNY CENTRAL Inverters of the HE-20 and CP Series - Unpacking and Transport Manual SCxxxHE20-AP-IEN114110.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SCxxxCP_HE20-AP-IEN114110
  • Version: 1.0
Mounting and Technical Data - Sunny Main Box / Sunny Main Box Cabinet SMB_SMB-C-TI-en-30.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SMB_SMB-C-TI-en-30
  • Version: 3.0
Q at Night - Reactive power outside feed-in operation with the SUNNY CENTRAL series CP XT, CP-JP and CP-US Q-at-Night-TI-en-11.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Q-at-Night-TI-en-11
  • Version: 1.1
SUNNY CENTRAL COMMUNICATION CONTROLLER SC-COM-TI-en-13.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-COM-TI-en-13
  • Version: 1.3
Installation at high altitudes - Design of Central Inverters for Mounting Locations above 2,000 m MSL SUNNY CENTRAL xxxCP XT CP-Hoehenaufst-TI-en-12.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: CP-Hoehenaufst-TI-en-12
  • Version: 1.2
Transportation and Installation Requirements - SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT SCCPXT-TA-E7-en-72.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SCCPXT-TA-E7-en-72
  • Version: 7.2
Technical Information - SC-COM Modbus® Interface for SUNNY CENTRAL of the production series CP, CP-US, CP-JP and HE-20 SC-COM-MODBUS-TB-en-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-COM-MODBUS-TB-en-22
  • Version: 2.2
Technical Information - Communit Communit-TI-A1-en-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Communit-TI-A1-en-22
  • Version: 2.2
Información técnica - Communit Communit-TI-A1-es-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Communit-TI-A1-es-22
  • Version: 2.2
Technical Information - Plant Communication in Large-Scale PV Power Plants SC-PO-TI-en-34.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-PO-TI-en-34
  • Version: 3.4
Technical Information - Requirement for MV Transformers and Transformer for Internal Power Supply for SUNNY CENTRAL SC_Trafo-TI-en-63.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC_Trafo-TI-en-63
  • Version: 6.3

Installation Guide

SUNNY CENTRAL 500CP / 630CP / 720CP / 760CP / 800CP - SMB Connection Kit SMB-Kit-BB-IEN111011.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SMB-Kit-BB-IEN111011
  • Version: 1.1
Installation Manual - SUNNY STRING-MONITOR SSM8-21-BS / SSM16-21-BS / SSM8-21-BS-JP / SSM16-21-BS-JP SSMxx-21-IA-BS-JP-en-20.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SSMxx-21-IA-BS-JP-en-20
  • Version: 2.0
Installation Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT / 1000CP XT SCCPXT-IA-E7-en-45.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SCCPXT-IA-E7-en-45
  • Version: 4.5
SUNNY CENTRAL CP and HE-20 - Sealing - Additional sheet Plomb-BB-IEN112920.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: Plomb-BB-IEN112920
  • Version: 2.0
Installation Manual - Retrofitting of the Option 'Noise Reduction' SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE SCCPXT-SCS_NR-IA-en-11.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SCCPXT-SCS_NR-IA-en-11
  • Version: 1.1

Data sheet

Premium project management - Worldwide expertise and seamless support Project-Management-DEN122114W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: Project-Management-DEN122114
  • Version: 1.4
SMA DEIE Interface - Communication and control interface for PV-Plants >250 kW DEIE_Interface-DEN142111W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: DEIE_Interface-DEN142111
  • Version: 1.1
SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT - The extended CP: more features included SC500CP-760CP-DEN1530-V21web.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: SC500CP-760CP-DEN1530-V21
  • Version: 2.1

Brochure

OPTIPROTECT - Intelligent error management for higher plant yields OPTIPRO-AEN121210W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: OPTIPRO-AEN121210
  • Version: 1.0
Experience meets Peak Performance - The Megawatt Solution Megawatt-KEN122210W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: Megawatt-KEN122210
  • Version: 1.0
SMA Power Plant Solutions - Solutions for Profitable PV Power Plants - Cutting-Edge Applications for Utility-Scale PV Projects KOMPETENZ_PPS-KEN131230W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: KOMPETENZ_PPS-KEN131230
  • Version: 3.0
INSIGHTS Edition 01 - Extreme Conditions Require Experience INSIGHTS01-AEN132412W.PDF
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: INSIGHTS01-AEN132412W
  • Version: 1.2
INSIGHTS Edition 03 - EMERGING PV MARKETS INSIGHTS03-AEN132411W.PDF
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: INSIGHTS03-AEN132411W
  • Version: 1.1
INSIGHTS Edition 04 - QUALITY IS THE FUTURE INSIGHTS04-AEN130710W.PDF
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: INSIGHTS04-AEN130710
  • Version: 1.0
INSIGHTS Edition 02 - PV POWER PLANTS: THE FUTURE OF POWER GRIDS INSIGHTS02-AEN120810W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: INSIGHTS02-AEN120810
  • Version: 1.0
Quality Makes the Difference - Your partner for utility-scale PV EN – now and in the future QUALI-AEN132613W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: QUALI-AEN132613W
  • Version: 1.3
SMA Service - Maintenance for Optimum Plant Performance // Service for Sunny Central Inverters and Medium-Voltage Components SC_FS_WARTUNG-KEN1609.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: SC_FS_WARTUNG-KEN1609
  • Version: 1.0
SMA SERVICE FOR PV POWER PLANTS - Successful Projects with Sunny Central System Solutions SERVICE-SC-KEN1609.pdf
  • Type: Brochure
  • Language: International
  • Number: SERVICE-SC-KEN1609
  • Version: 3.1

Planning guidelines

Planning of a PV Generator - Planning Guidelines DC-PL-en-11.pdf
  • Type: Planning guidelines
  • Language: English (Worldwide)
  • Number: DC-PL-en-11
  • Version: 1.1

Operating Instructions

SUNNY CENTRAL COMMUNICATION CONTROLLER - Operating Manual SC-COM-BE-en-20.pdf
  • Type: Operating Instructions
  • Language: English (Worldwide)
  • Number: SC-COM-BE-en-20
  • Version: 2.0

Maintenance protocol

Maintenance Report - SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT SCCPXT-WP-E7-en-34.pdf
  • Type: Maintenance protocol
  • Language: English (Worldwide)
  • Number: SCCPXT-WP-E7-en-34
  • Version: 3.4

Maintenance Manual

Maintenance Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT / 1000CP XT SCCPXT-WA-E7-en-35.pdf
  • Type: Maintenance Manual
  • Language: English (Worldwide)
  • Number: SCCPXT-WA-E7-en-35
  • Version: 3.5

Certificate

Type Certificate - BDEW for SUNNY CENTRAL CP (XT) ZE_BDEW_SCxxxxCPXT_en_61.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_BDEW_SCxxxxCPXT_en_61
  • Version: 6.1
Made in EU certificate Qinto Conto Energia §4.4.1 & 4.6.1 - SUNNY BOY/SUNNY MINI CENTRAL/SUNNY TRIPOWER/SUNNY CENTRAL SB-STP-SC-ZE-FIC-IT-en-12.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: SB-STP-SC-ZE-FIC-IT-en-12
  • Version: 1.2
Factory Inspection Certificate for Made in European Union SUNNY BOY / SUNNY ISLAND / SUNNY TRIPOWER / SUNNY CENTRAL ZE_Made-in-EU_SB-STP-SC_en_12.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_Made-in-EU_SB-STP-SC_en_12
  • Version: 1.2

User Manual

User Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT / 1000CP XT SCCPXT-BA-E7-en-56.pdf
  • Type: User Manual
  • Language: English (Worldwide)
  • Number: SCCPXT-BA-E7-en-56
  • Version: 5.6