SUNNY TRIPOWER CORE1

SUNNY TRIPOWER CORE1

Stands on its own

The Sunny Tripower CORE1 is the world’s first free-standing string inverter for decentralized rooftop and ground-based PV systems as well as covered parking spaces. The CORE1 is the third generation in the successful Sunny Tripower product family and is revolutionizing the world of commercial inverters with its innovative design. SMA engineers developed an inverter that combines a unique design with an innovative installation method to significantly reduce installation time and provide all target groups with a maximum return on investment.

From delivery and installation to operation, the Sunny Tripower CORE1 generates widespread savings in logistics, labor, materials and services. Commercial PV installations are now quicker and easier to complete than ever before.

Cost-Effective

  • Floor-mounted device easy to install
  • No DC fuses required
  • Integrated DC disconnector


Highly Integrated

  • Integrated WLAN access with any mobile device
  • 12 direct string inputs reduce labor and material costs
  • AC/DC overvoltage protection (optional)


Fastest Installation

  • Fast grid connection due to easy inverter configuration and commissioning
  • Completely accessible connection areas


Maximum Yields

  • Up to 150% DC:AC ratio
  • Six independent MPP trackers guarantee optimal energy production for every use, even in shading

MODBUS PROTOCOL INTERFACE

Language

Technical information

Technical Information - SMA SENSOR MODULE (MD.SEN-40) - List of Compatible Products MDSEN-40-TI-en-11.pdf
  • Type: Technical information
  • Language: International
  • Number: MDSEN-40-TI-en-11
  • Version: 1.1
Integrated Plant Control and Q on Demand 24/7 - SUNNY TRIPOWER IPC-QoD24-7-STP-TI-en-16.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: IPC-QoD24-7-STP-TI-en-16
  • Version: 1.6
Technische Information - Modbus®-Schnittstelle // Technical Information - Modbus® Interface SMA_Modbus-de-en_V22.zip
  • Type: Technical information
  • Language: International
  • Number: SMA_Modbus-de-en_V22
  • Version: 2.2
Technical Information - Impedance at 175 Hz for PV Systems in France SUNNY BOY / SUNNY MINI CENTRAL / SUNNY TRIPOWER / FLX PRO Impedanz-175Hz-TI-en-29.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Impedanz-175Hz-TI-en-29
  • Version: 2.9
Technical Information - Efficiency and Derating SUNNY BOY / SUNNY BOY STORAGE / SUNNY TRIPOWER / SUNNY MINI CENTRAL / SUNNY HIGHPOWER WirkungDerat-TI-en-44.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: WirkungDerat-TI-en-44
  • Version: 4.4
Technische Information - SunSpec®-Modbus®-Schnittstelle // Technical Information - SunSpec® Modbus® Interface SunSpec_Modbus-de-en_V20.zip
  • Type: Technical information
  • Language: International
  • Number: SunSpec_Modbus-de-en_V20
  • Version: 2.0
Technical Information - Temperature Derating SUNNY BOY / SUNNY TRIPOWER Temp-Derating-TI-en-14.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Temp-Derating-TI-en-14
  • Version: 1.4
Parameter list for STP 50-40 / STP 50-US-40 / STP 50-JP-40 (Sunny Tripower CORE1 / Sunny Tripower CORE1-US / Sunny Tripower CORE1-JP) PARAMETER-HTML_STP50_V10.zip
  • Type: Technical information
  • Language: International
  • Number: PARAMETER-HTML_STP50_V10
  • Version: 1.0
Technical Information - Short-Circuit Currents - Information on short-circuit currents of SMA PV inverters Iscpv-TI-en-14.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Iscpv-TI-en-14
  • Version: 1.4

Certificate

Certificate of compliance with EN61000-3-x and EN61000-6-x for SUNNY TRIPOWER CORE1 (STP 50-40) ZE_EN 61000-3-x_STP 50-40_en_10.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_EN 61000-3-x_STP 50-40_en_10
  • Version: 1.0
Abu Dhabi QCC certificate - STP 15000TL-30 / STP 20000TL-30 / STP 25000TL-30 / STP 50-40 / STP 60-10 ZE_QCC_STPTL-30_STP50-40_STP60-10_en_10.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_QCC_STPTL-30_STP50-40_STP60-10_en_10
  • Version: 1.0
Type Certificate - BDEW for SUNNY STRIPOWER CORE1 (STP 50-40) ZE_BDEW_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_BDEW_STP50-40_en_10
  • Version: 1.0
Certificate of compliance with the requirements of the standard Dubai Electricity & Water Authority - SUNNY TRIPOWER CORE1 (STP 50-40) ZE_IEC62109_DEWA_U17-0603_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_IEC62109_DEWA_U17-0603_STP50-40_en_10
  • Version: 1.0
Certificate of compliance NRS 097-2-1 - SUNNY TRIPOWER (STP 50-40) ZE_NRS097_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_NRS097_STP50-40_en_10
  • Version: 1.0
Certificate IEC 62109-x - SUNNY TRIPOWER CORE1 (STP 50-40) ZE_IEC62109_U-17-0542_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_IEC62109_U-17-0542_STP50-40_en_10
  • Version: 1.0
Certificate of compliance EN 50438:2013 - SUNNY TRIPOWER CORE1 (STP 50-40) ZE_EN50438_U17-0607_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_EN50438_U17-0607_STP50-40_en_10
  • Version: 1.0
Certificate G59/3 - SUNNY TRIPOWER CORE1 (STP 50-40) ZE_G59-3_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_G59-3_STP50-40_en_10
  • Version: 1.0
TEST REPORT - PO12.3 Testing of LVRT behaviour - SUNNY TRIPOWER CORE1 (STP 50-40) ZE_PO12-3_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_PO12-3_STP50-40_en_10
  • Version: 1.0
Certificate EN 50438/2013 - SUNNY TRIPOWER CORE1 (STP 50-40) HK_EN50438_2013_STP50-40_en_12.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: HK_EN50438_2013_STP50-40_en_12
  • Version: 1.2
Declaration of Conformity - Resolution n°7 - Addendum to Amendment n°1 of the Philippine Grid Code ZE_Res_No7_STP_en_12.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_Res_No7_STP_en_12
  • Version: 1.2
Certificate of Compliance IEC 61727 - SUNNY TRIPOWER CORE1 (STP 50-40) ZE_IEC61727_U17-0624_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_IEC61727_U17-0624_STP50-40_en_10
  • Version: 1.0
Certificate of compliance DIN V VDE 0126-1-1/A1 - Automatic disconnection device between a generator and the public low-voltage grid - STP 50-40 ZE_VDE0126_U17-0530_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_VDE0126_U17-0530_STP50-40_en_10
  • Version: 1.0
Certificate of Suitability AS4777 - SUNNY TRIPOWER CORE 1 (STP 50-40) ZE_AS4777_CoS_STP50-40_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_AS4777_CoS_STP50-40_en_10
  • Version: 1.0

Operating Instructions

Operating manual - SUNNY TRIPOWER CORE1 STP50-40-BE-en-12.pdf
  • Type: Operating Instructions
  • Language: English (Worldwide)
  • Number: STP50-40-BE-en-12
  • Version: 1.2

Firmware

SUNNY TRIPOWER CORE1 - firmware update 1.03.04.R. It is mandatory that you read the included READ_ME.pdf FW1_03_04_R_STP50-40.zip
  • Type: Firmware
  • Language: International
  • Number: FW1_03_04_R_STP50-40
  • Version: 1.03.04.R

Manufacturers Declaration

Manufacturer Declaration - Compliance SMA inverters with the requirements of the Chilean technical regulation HK_STP-NTCO_NTSyCS_en_14.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: HK_STP-NTCO_NTSyCS_en_14
  • Version: 1.4
Declaration of Conformity - Resolution n°7 - Addendum to Amendment n°1 of the Philippine Grid Code ZE_Res_No7_STP_en_11.pdf
  • Type: Manufacturers Declaration
  • Language: International
  • Number: ZE_Res_No7_STP_en_11
  • Version: 1.1
Manufacturer’s Declaration - Confirmation of integrated all-current sensitive residual-current monitoring unit (RCMU) ZE_HK_RCMU_en_15.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: ZE_HK_RCMU_en_15
  • Version: 1.5
Manufacturer’s Declaration - Efficiency Warranty MPS-ZE-EffiLifetime-en-12.pdf
  • Type: Manufacturers Declaration
  • Language: International
  • Number: MPS-ZE-EffiLifetime-en-12
  • Version: 1.2
EU Declaration of Conformity - SUNNY TRIPOWER (STP 50-40) ZE_CE_STP50-40_en_10.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: ZE_CE_STP50-40_en_10
  • Version: 1.0
Manufacturer’s Declaration - Compliance with ENA EREC G100 requirements HK_ENA_EREC_G100_en_11.pdf
  • Type: Manufacturers Declaration
  • Language: International
  • Number: HK_ENA_EREC_G100_en_11
  • Version: 1.1
Manufacturer’s Declaration - Confirmation of Compliance with the Requirements of C 10/11:2012 ZE-C10_11_2012-en-23.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: ZE-C10_11_2012-en-23
  • Version: 2.3

Warranty

Order Form - SMA Extended Warranty Comfort for Sunny Boy, Sunny Tripower, Sunny Highpower and MLX BGVCOMFORT-en-38.pdf
  • Type: Warranty
  • Language: English (Worldwide)
  • Number: BGVCOMFORT-en-38
  • Version: 3.8
Order Form - SMA Extended Warranty Comfort (only for Australien Market) for Sunny Boy, Sunny Tripower, Sunny Highpower and MLX BGVCOMFORT-en_au-38.pdf
  • Type: Warranty
  • Language: English (Worldwide)
  • Number: BGVCOMFORT-en_au-38
  • Version: 3.8
Order Form - SMA Extended Warranty Active for Sunny Boy, Sunny Tripower, Sunny Highpower, MLX and Inverter Manager BGVACTIVE-en-37.pdf
  • Type: Warranty
  • Language: International
  • Number: BGVACTIVE-en-37
  • Version: 3.7
Terms and Conditions applicable to the SMA Limited Warranty Contracts COM-RES-EWTC-en-12.pdf
  • Type: Warranty
  • Language: English (Worldwide)
  • Number: COM-RES-EWTC-en-12
  • Version: 1.2
SMA Limited Factory Warranty COM-RES-GBED-en-42.pdf
  • Type: Warranty
  • Language: English (Worldwide)
  • Number: COM-RES-GBED-en-42
  • Version: 4.2

Installation Guide

Installation Manual - SMA SENSOR MODULE - MD.SEN-40 (PC-SENS.BG1) MDSEN-40-IA-en-10.pdf
  • Type: Installation Guide
  • Language: International
  • Number: MDSEN-40-IA-en-10
  • Version: 1.0
Installation Manual - SMA I/O-MODULE - MD.IO-40 (PC-PWC.BG1) MD-IO-40-IA-en-10.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: MD-IO-40-IA-en-10
  • Version: 1.0
Installation manual - SMA RS485 MODULE - MD.485-40 (PC-485.BG1) MD485-40-IA-en-10.pdf
  • Type: Installation Guide
  • Language: International
  • Number: MD485-40-IA-en-10
  • Version: 1.0
Installation Manual - ANTENNA EXTENSION KIT (EXTANT-40) EXTANT-40-IA-en-10.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: EXTANT-40-IA-en-10
  • Version: 1.0

Quick reference guide

Quick Reference Guide // クイックガイド - ANTENNA EXTENSION KIT (EXTANT-40) EXTANT-40-IS-JP-xx-10.pdf
  • Type: Quick reference guide
  • Language: International
  • Number: EXTANT-40-IS-JP-xx-10
  • Version: 1.0

Forms

APPLICATION FOR SMA GRID GUARD-CODE (only for Australien Market) GRIDGUARD-en_au-33.pdf
  • Type: Forms
  • Language: International
  • Number: GRIDGUARD-en_au-33
  • Version: 3.3
APPLICATION FOR THE CREATION OF A PUK PUK-ANTRAG-en-20.pdf
  • Type: Forms
  • Language: International
  • Number: PUK-ANTRAG-en-20
  • Version: 2.0
APPLICATION FOR SMA GRID GUARD-CODE GRIDGUARD-en-32.pdf
  • Type: Forms
  • Language: English (Worldwide)
  • Number: GRIDGUARD-en-32
  • Version: 3.2

Brochure

SUNNY TRIPOWER CORE1 - Stands on its own. STPCORE1-KEN1702.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: STPCORE1-KEN1702
  • Version: 1.1
SUNNY TRIPOWER CORE1 - Stands on its own. (only for Australien Market) STPCORE1-KAU1702.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: STPCORE1-KAU1702
  • Version: 1.1

Data sheet

SUNNY TRIPOWER CORE1 - Stands on its own STP50-40-DEN1728-V20web.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: STP50-40-DEN1728-V20
  • Version: 2.0