SUNNY ISLAND 4.4M / 6.0H / 8.0H

SUNNY ISLAND 4.4M / 6.0H / 8.0H

The most reliable  solution – easier than ever

With the new generation of devices, the tried-and-tested Sunny Island battery inverters are easier and more affordable to install than ever with 10 year warranty.

WLAN communication now included

Proven technology
now even more affordable

The Sunny Island has been installed more than 70,000 times worldwide. With the new generation, installers and PV system operators benefit from an even more user-friendly battery inverter.

  • Lower system costs thanks to fewer components
  • Faster installation and commissioning with a simple user interface
  • Warranty period extended to 10 years
Sunny Island - Proven technology now even more affordable

Sunny Island - Communicative in all areas

Communicative in all areas

Thanks to its integrated user interface and standard WLAN and Ethernet interfaces, the Sunny Island can be immediately and easily configured and monitored via smartphones or tablets.

  • Uses standard Ethernet and WLAN interfaces
  • Webconnect for faster and easier PV system monitoring with Sunny Portal / Sunny Places
  • Local monitoring via web interface
  • Optimized data logging for maximum transparency, even without continuous online access


Fast commissioning in eight steps


Can be used flexibly in private homes and commercial enterprises

The Sunny Island has maximum flexibility, from operation in remote areas to off-grid commercial or home energy management. It gives planners total freedom in the size and type of system and the battery. Works with battery backup systems and off-grid systems.

  • Ideal for retrofits or modular expansions of single- and three-phase systems in the 1 to 30 kW range
  • All lead-acid batteries and over 20 different lithium-ion batteries can be used
  • Can be expanded with SMA Multicluster-Technologie for systems in the 20 to 300 kW range

Off-grid systems

Off-grid systems

Its high protection class, wide temperature range and exceptional overload capacity always provide the kind of security in the electricity supply that is needed for off-grid use. Intelligent load and energy management ensures operation even in critical situations and allows any appliance to be switched on even in the event of high inrush currents or harsh ambient conditions.


Always a reliable electricity supply

The Sunny Island runs reliably under even the most extreme conditions – without compromising its efficiency.

  • Exceptionally high overload capacity ensures a safe electricity supply, even in critical situations
  • IP54 for operation even in extreme environments
Sunny Island - Always a reliable electricity supply

Possible system configurations with Sunny Island 4.4M / 6.0H / 8.0M

Single, 1-phasig

Single, 1-phase
SI 6.0H or SI 8.0H for system capacities from 3 kW to 8 kW.


Single Cluster, 3-phasig

Single cluster, 3-phase
Up to three SI 6.0H or SI 8.0H can be mixed flexibly for system capacities from 6 kW to 24 kW.

Single Cluster, 1-phasig

Single cluster, 1-phase
Up to three SI 6.0H or SI 8.0H can be mixed flexibly for system capacities from 6 kW to 24 kW.

Multicluster, 3-phasig

Multicluster, 3-phase
Three devices per cluster for system capacities from 24 kW to 300 kW (SI 6.0H: 6 to 36 devices, SI 8.0H: 6 to 30 devices) SI 6.0H, SI 8.0H and SI 5048 clusters can be mixed flexibly.


Sunny Island 4.4M / 6.0H / 8.0H - FAQs

 

What does my optimal PV system with the Sunny Island look like?
With the SMA Sunny Design planning software, you can configure your system to fit your personal needs in just a few steps.

How do I install the grounding for a stand-alone grid?
Which PV inverter is suitable for my stand-alone grid?
Which lithium-ion batteries are compatible?

You can find the answers to your questions in our useful manuals.

Language

Brochure

Solar Solutions for Off-grid Power Supply - Clean Energy. Anywhere. SHS_HYBRID-AEN121410W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: SHS_HYBRID-AEN121410
  • Version: 1.0
SUNNY ISLAND System Guide - System Solutions for Reliable Off-Grid Power Supply SISYSGUIDE-KEN140421.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: SISYSGUIDE-KEN140421
  • Version: 2.1

Technical information

Technical Information - Battery Management of the SUNNY ISLAND - Gentle charging control for lead-acid batteries based on current state of the battery SI_Batteriemanagement-TI-en-21.pdf
  • Type: Technical information
  • Language: International
  • Number: SI_Batteriemanagement-TI-en-21
  • Version: 2.1
Technical Information - SMA Flexible Storage System - Safety Concept Explanation FSS-SafetyConcept-TI-en-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: FSS-SafetyConcept-TI-en-22
  • Version: 2.2
Batteries in Sunny Island Systems - List of Approved Batteries SI_LiIon-TI-en-37.pdf
  • Type: Technical information
  • Language: International
  • Number: SI_LiIon-TI-en-37
  • Version: 3.7
Technical Information - SMA Flexible Storage System / SMA Integrated Storage System - Disclosure of System Interface for Remote Control and Remote Parameterization FSS-ISS-HoMan-Foerderprogamm-TI-en-11.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: FSS-ISS-HoMan-Foerderprogamm-TI-en-11
  • Version: 1.1
Technical information - SUNNY BOY SMART ENERGY / SUNNY BOY STORAGE / SUNNY ISLAND - Energy Efficiency of PV Storage Systems BattWr-Efficiency-TI-en-11.pdf
  • Type: Technical information
  • Language: International
  • Number: BattWr-Efficiency-TI-en-11
  • Version: 1.1
Technische Information - Modbus®-Schnittstelle // Technical Information - Modbus® Interface SMA_Modbus-de-en_V19.zip
  • Type: Technical information
  • Language: International
  • Number: SMA_Modbus-de-en_V19
  • Version: 1.9
Technical Information - SMA SMART HOME - Battery Charging Management with Time-of-Use Energy Tariffs SmartHome_Time-of-use-TI-en-11.pdf
  • Type: Technical information
  • Language: International
  • Number: SmartHome_Time-of-use-TI-en-11
  • Version: 1.1
Technische Information - Modbus®-Schnittstelle // Technical Information - Modbus® Interface SMA_Modbus-de-en_V22.zip
  • Type: Technical information
  • Language: International
  • Number: SMA_Modbus-de-en_V22
  • Version: 2.2
Parameter list for SUNNY ISLAND 4.4M / 6.0H / 8.0H (SI4.4M-12 / SI6.0H-12 / SI8.0H-12) PARAMETER-HTML_SI44M-80H-12_V11.zip
  • Type: Technical information
  • Language: International
  • Number: PARAMETER-HTML_SI44M-80H-12_V11
  • Version: 1.1
Technical Information - Grounding in Off-Grid Systems - Design of TN and TT Off-Grid Systems SI-OffGrid-Grounding-TI-en-11.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SI-OffGrid-Grounding-TI-en-11
  • Version: 1.1

Forms

APPLICATION FOR THE CREATION OF A PUK PUK-ANTRAG-en-20.pdf
  • Type: Forms
  • Language: International
  • Number: PUK-ANTRAG-en-20
  • Version: 2.0

Quick reference guide

SMA Flexible Storage System SI44M-80H-12-FSS-IAU-xx-10W.pdf
  • Type: Quick reference guide
  • Language: International
  • Number: SI44M-80H-12-FSS-IAU-xx-10
  • Version: 1.0

Technical Manual

Off-Grid Questionnaire Off-Grid-Questionnaire-en-240415.pdf
  • Type: Technical Manual
  • Language: English (Worldwide)
  • Number: Off-Grid-Questionnaire-en-240415
  • Version: 1.2
SUNNY ISLAND - Generator - Whitepaper SIGEN-13FE0914.pdf
  • Type: Technical Manual
  • Language: English (Worldwide)
  • Number: SIGEN-13:FE0914
  • Version: 1.3
INFORMATION SHEET FOR SUNNY ISLAND SYSTEMS INFOOFFGRID-TI-en-16W.pdf
  • Type: Technical Manual
  • Language: English (Worldwide)
  • Number: INFOOFFGRID-TI-en-16
  • Version: 1.6
Off-Grid Questionnaire Off-Grid-Questionnaire-en-240415doc.doc
  • Type: Technical Manual
  • Language: English (Worldwide)
  • Number: Off-Grid-Questionnaire-en-240415doc
  • Version: 1.2

Planning guidelines

Planning Guidelines - SMA SMART HOME - The System Solution for Greater Independence SI-HoMan-PL-en-50.pdf
  • Type: Planning guidelines
  • Language: International
  • Number: SI-HoMan-PL-en-50
  • Version: 5.0
Planning Guidelines - Design of Off-Grid Systems with Sunny Island 4.4M / 6.0H / 8.0H Devices Designing-OffGridSystem-PL-en-23.pdf
  • Type: Planning guidelines
  • Language: International
  • Number: Designing-OffGridSystem-PL-en-23
  • Version: 2.3
Planning Guidelines - SMA FLEXIBLE STORAGE SYSTEM WITH BATTERY-BACKUP FUNCTION - Circuitry Overviews, Schematic Diagrams and Material Lists SI-Ersatzstrom-PL-en-23.pdf
  • Type: Planning guidelines
  • Language: International
  • Number: SI-Ersatzstrom-PL-en-23
  • Version: 2.3

Data sheet

SUNNY ISLAND 4.4M / 6.0H / 8.0H - The most reliable all-purpose solution—easier than ever SI44M_60H_80H-DEN1730-V12web.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: SI44M_60H_80H-DEN1730-V12
  • Version: 1.2

Operating Instructions

Operating Manual - SUNNY ISLAND 4.4M / 6.0H / 8.0H SI44M-80H-12-BE-en-10.pdf
  • Type: Operating Instructions
  • Language: English (Worldwide)
  • Number: SI44M-80H-12-BE-en-10
  • Version: 1.0