SMA FUEL SAVE CONTROLLER Data Acquisition Module

SMA FUEL SAVE CONTROLLER

Easy integration of photovoltaics into fossil-fuelled power generation with SMA hybrid system technology

The SMA Fuel Save Controller is the central component of the SMA solution for hybrid systems consisting of photovoltaics and fossil-fuelled gensets. It ensures the demand-oriented control of the photovoltaic system dependent on the plant’s load and genset characteristics. Thus the gensets operate in a reliable and stable state even with high levels of photovoltaics.
Together with the Fuel Save Controller, SMA inverters fulfil comprehensive grid management functions within the system. The SMA hybrid system technology is scalable on a modular basis and can be adapted to the specific requirements of the power plant. Furthermore, the Fuel Save Controller offers the opportunity to monitor the hybrid system remotely. This assures optimum energy management for the plant operator and guarantees efficient and flexible system performance.

Ease of use

  • Several available operation modes allow for easy bolt-on integration with genset systems
  • Exchange realtime data with other devices and systems through the standard Modbus® communication protocol

Stability

  • Automatic regulation of PV power according to load and state of gensets
  • Reverse power protection functionality
  • Optimisation and communication features available

Flexibility

  • Plant and system parameters are fully configurable
  • Modular design allows for most system setups
  • PLC-based modular system with proven industrial grade components

Scalability

  • Supports future system expansion (for example, increase in the amount of PV)
  • Prepared for future integration of energy storage systems

Contact

SMA Australia Pty Ltd
Level 1, 213 Miller Street,
North Sydney NSW 2060
Australia

PO Box 645,
North Ryde BC, NSW 1670,
Australia

Tel. +61 (02) 9491 4200
Fax +61 (02) 9491 4290
Freecall 1800 SMA AUS

info@SMA-Australia.com.au
www.SMA-Australia.com.au

SUNNY CENTRAL 800CP XT

SUNNY CENTRAL 800CP XT / 850CP XT / 900CP XT

The extended CP XT: peak output up to 1 megawatt

  • Max. permissible DC voltage: 1000 V
  • Nominal AC power (@ 50 °C): 800 kVA / 850 kVA / 900 kVA
Continue »

SUNNY CENTRAL 500CP XT

SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT

The extended CP XT: more features included

  • Max. permissible DC voltage: 1000 V
  • Nominal AC power (@ 50 °C): 500 kVA / 630 kVA / 720 kVA / 760 kVA
Continue »

SUNNY TRIPOWER 15000TL-10 Economic Excellence

SUNNY TRIPOWER 15000TL / 20000TL ECONOMIC EXCELLENCE

The expert cost saver for high-yield, commercial plants

  • Topology: Transformerless
  • Max. DC-voltage: 1000 V
  • Max. apparent AC power: 15000 VA / 20000 VA
Continue »

SUNNY TRIPOWER 10000TL

SUNNY TRIPOWER 10000TL / 12000TL / 15000TL / 17000TL

The three-phase inverter for easy plant design

  • Topology: Transformerless
  • Max. DC-voltage: 1000 V
  • Max. apparent AC power: 10000 VA / 12000 VA / 15000 VA / 17000 VA
Continue »

Hybrid energy supply systems in industrial applications require particular properties of the inverter.

Learn more »

Contact

SMA Australia Pty Ltd
Level 1, 213 Miller Street,
North Sydney NSW 2060
Australia

PO Box 645,
North Ryde BC, NSW 1670,
Australia

Tel. +61 (02) 9491 4200
Fax +61 (02) 9491 4290
Freecall 1800 SMA AUS

info@SMA-Australia.com.au
www.SMA-Australia.com.au

Language

Data sheet

SMA FUEL SAVE CONTROLLER - Integrating photovoltaics into fossil-fueled power generation systems FSC-DEN133116W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: FSC-DEN133116
  • Version: 1.6
SMA FUEL SAVE CONTROLLER only for Australien Market - Integrating photovoltaics into fossil-fueled power generation systems FSC-DAU131714W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: FSC-DAU131714
  • Version: 1.4

Brochure

SMA Fuel Save Solution - The SMA solution for industrial photovoltaic diesel hybrid systems PVDIESELHYBRID-AEN132111.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: PVDIESELHYBRID-AEN132111
  • Version: 1.1
SMA FUEL SAVE SOLUTION - SySTEM DESIGNS - Making your fossil-fueled energy systems future-proof PV-DIESEL_LEAFLET-KEN142110W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: PV-DIESEL_LEAFLET-KEN142110
  • Version: 1.0

Technical information

DATA ACQUISITION MODULE - Technical information - Connecting Summation Current Transformers to a Data Acquisition Module DAQ-Summenstrom-TI-en-11.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: DAQ-Summenstrom-TI-en-11
  • Version: 1.1
SMA FUEL SAVE CONTROLLER - PV Diesel Hybrid Systems - Technical Information: Functional Description FSC10_System_TI_en_10.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: FSC10_System_TI_en_10
  • Version: 1.0
Technical Description - SMA FUEL SAVE CONTROLLER (FSC11CONT) Modbus® Interface FSC11_Modbus-TB-en-10.pdf
  • Type: Technical information
  • Language: International
  • Number: FSC11_Modbus-TB-en-10
  • Version: 1.0
Technical Information - Plant Communication in Large-Scale PV Power Plants SC-PO-TI-en-34.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-PO-TI-en-34
  • Version: 3.4

Contact

SMA Australia Pty Ltd
Level 1, 213 Miller Street,
North Sydney NSW 2060
Australia

PO Box 645,
North Ryde BC, NSW 1670,
Australia

Tel. +61 (02) 9491 4200
Fax +61 (02) 9491 4290
Freecall 1800 SMA AUS

info@SMA-Australia.com.au
www.SMA-Australia.com.au