AS/NZS 4777.2:2020 Technical Information (SBx.x-1VL-40, SBx.x-1AV-41, STPxx.x-3AV-40, STP 50-41)
AS/NZS 4777.2:2020 Technical Information (STP 110-60)
AS/NZS 4777.2:2020 Technical Information (STP 12-50, STP 15-50, STP 20-50, STP 25-50)
AS/NZS 4777.2:2020 Technical Information - Sunny Island (SI6.0H-13/SI8.0H-13)

SMA Inverters AS/NZS 4777.2:2020 Compliance Status

For SMA Inverters that comply to AS/NZS 4777.2:2020 and listed on CEC, the listing date will be shown as DD/MM/YYYY.

Sunny Boy 1.5 / 2.5

Model

SB1.5-1VL-40
SB2.5-1VL-40

 

CEC listing

17/10/2022

 

Minimum Firmware

3.11.05.R

 

DC Isolator Certificate

SAA-202733-EA

SAA-202733-EA (addendum 1a)

Sunny Boy 3.0 / 4.0 / 5.0 / 6.0

Model

SB3.0-1AV-41
SB4.0-1AV-41
SB5.0-1AV-41
SB6.0-1AV-41

 

CEC listing

29/06/2022

 

Minimum Firmware

04.00.55.R

 

DC Isolator Certificate

SAA-202733-EA (addendum 1a)

SAA-202733 (addendum 2a)

Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0

Model

STP3.0-3AV-40
STP4.0-3AV-40
STP5.0-3AV-40
STP6.0-3AV-40

 

CEC listing

01/07/2022

 

Minimum Firmware

3.11.11.R

 

DC Isolator Certificate

SAA-202733 (addendum 2a)

SAA-202733 (addendum 3a)

Sunny Tripower 8.0 / 10.0

Model

STP8.0-3AV-40
STP10.0-3AV-40

 

CEC listing

05/07/2022

 

Minimum Firmware

3.11.11.R

 

DC Isolator Certificate

SAA-202733 (addendum 3a)

Sunny Tripower X 12 / 15 / 20 / 25

Model

STP12-50
STP15-50
STP20-50
STP25-50

 

CEC listing

15/06/2023

 

Minimum Firmware

2.06.04.R

 

DC Isolator Certificate

Certificate AZ 69025885

Sunny Tripower CORE1

Model

STP50-41

 

CEC listing

01/07/2022

 

Minimum Firmware

3.14.05.R

 

DC Isolator Certificate

DC Switch declaration 

SAA-202733 (addendum 4a)

Sunny Tripower CORE2

Model

STP110-60

 

CEC listing

22/07/2022

 

Minimum Firmware

1.00.12.R

 

DC Isolator Certificate

Certificate AZ 69025885

Sunny Island 6.0H / 8.0H

Model

SI6.0H-13

SI8.0H-13

 

CEC listing

14/09/2023

(Grid Connect Inverter - Battery Only)*

 

Minimum Firmware

3.30.12.R

 

DC Isolator Certificate

n/a

 

*(Sunny Island is also on the CEC Approved Inverter list for inverter category 'Stand alone inverter with Generator Input Battery Only'.)

Inverters NOT in the process of becoming compliant to AS/NZS 4777.2:2020

The following currently CEC approved inverters will not be compliant to AS/NZS 4777.2:2020 and will not be CEC listed after December 18th, 2021.

Disclaimer

The information contained herein is subject to change. New information will be published as soon as it becomes available.

 

Last Updated: 16/12/2022

Sunny Boy Storage 3.7 / 5.0 / 6.0

Model

SBS3.7-10
SBS5.0-10
SBS6.0-10

Sunny Boy Storage 2.5

Model

SBS2.5-1VL-10

Sunny Tripower 15000TL / 20000TL / 25000TL

Model

STP15000TL-30
STP20000TL-30
STP25000TL-30

Sunny Tripower CORE1

Model

STP50-40

Sunny Tripower Storage 60

Model

STPS60-10